logo
logo
Zinc Assay Kit, BioAssay(TM)

Cat no: Z0449-91

Zinc Assay Kit, BioAssay(TM)

Zinc is an essential trace element and plays many key roles in metabolism. It is required for the activity of more than 300 enzymes, the structure of many proteins, and control of genetic expression. Zinc status affects basic processes of cell division, growth, differentiation, development, performance and aging through its requirement for synthesis and repair of DNA, RNA and protein. The common causes of zinc deficiency are low dietary intakes and low bioavailability. Clinical signs of zinc deficiency include acrodermatitis, low immunity, diarrhea, poor healing, stunting, hypogonadism, fetal growth failure, teratology and abortion. Zinc deficiency has now been recognized to be associated with many diseases such as malabsorption syndrome, chronic liver disease, chronic renal disease, sickle cell disease, diabetes, malignancy, and other chronic illnesses.\n\nSimple, direct and automation-ready procedures for measuring zinc concentration in biological samples are highly desirable in Research and Drug Discovery. Zinc assay kit is designed to measure zinc directly in biological samples without any pretreatment. The present method utilizes a chromogen that forms a colored complex specifically with zinc. The intensity of the color, measured at 425 nm, is directly proportional to the zinc concentration in the sample.\n\nKey Features:\nSensitive and accurate. Uses 50ul samples. Linear detection range 0.12uM (0.78 ug/dL) to 10uM (65 ug/dL) zinc in 96-well assay format.\nSimple and high-throughput. The procedure involves addition of a single working reagent and incubation for 30 min. Can be readily automated as a high-throughput assay for thousands of samples per day.\nImproved reagent stability and versatility. The optimized formulation has greatly enhanced reagent and signal stability. Cuvette or 96-well plate assay formats possible.\nLow interference in biological samples. No pretreatments are needed.\n\nApplications:\nDirect Assays: zinc in serum, plasma (no EDTA), urine, saliva etc.\nDrug Discovery/Pharmacology: effects of drugs on zinc metabolism.\nEnvironment: zinc determination in waste water, soil etc.\n\nKit Contents: (for 100 samples in 96-well assay)\nReagent A: 50ml Reagent B: 1ml Reagent C: 1ml\nEDTA: 1ml 100mM Zinc standard: 1ml 50uM\nStorage conditions. The kit is shipped at room temperature. Store Reagents B and C at -20 degrees C and other components at 4 degrees C. Shelf life: 6 months after receipt. Precautions: reagents are for research use only. Normal precautions for laboratory reagents should be exercised while using the reagents. Please refer to Material Safety Data Sheet for detailed information.\n\nProcedures:\nSample preparation: serum and plasma samples should be clear and free of turbidity or precipitates. If present, precipitates should be removed by filtration or centrifugation on a table centrifuge. Prior to assay, dilute serum or plasma samples 5-fold (n=5) in deionized water. Reagent preparation: equilibrate all reagents to room temperature. Vortex Reagents B and C before assay. Prepare enough Working Reagent: for each assay well, mix 200ul Reagent A, 4ul Reagent B and 4ul reagent C.\nProcedure using 96-well plate:\n1. Prepare standards in deionized water. Transfer 50ul of the Zn2+ standards into wells of a clear flat-bottom 96-well plate.\nNo STD+H2O Vol (ul) Zn2+ (uM)\n1 20ul+80ul 100 10.0\n2 15ul+85ul 100 7.5\n3 10ul+90ul 100 5.0\n4 5ul+95ul 100 2.5\n5 0ul+100ul 100 0\nTransfer 50ul Sample and Sample Blank (50ul sample+2ul EDTA) into wells of a Add 200ul working reagent and tap plate lightly to mix.\n2. Incubate 30 min at room temperature and read optical density at 425 nm (range 420-426 nm).\nProcedure using cuvette:\nTransfer 200ul standards, sample and sample blank (200ul Sample+8ul EDTA) to appropriately labeled tubes. Add 800ul working reagent and tap lightly to mix. Incubate 30 min and read optical density at 425nm.\n\nGeneral Considerations:\nBecause the shift in the peak wavelength (from 413nm to 425nm) is very small, the color change is not visually evident. Physiological concentrations of other metal ions do not interfere. Zn2+ chelators (e.g. EDTA, EGTA) should be avoided during sample preparation.\n\nCalculation:\nSubtract blank OD (water, #5) from the standard OD values and plot the DOD against Zn2+ standard concentrations. Calculate DOD for the Sample (= ODSAMPLE-ODSAMPLE BLANK). Determine the Sample Zn2+ concentration from the standard curve by non-linear regression fitting with a single-site saturation binding function (DOD=aпїЅ[Zn2+]/(b+[ Zn2+]). If the Zn2+ concentration is higher than 10uM, dilute sample in deionzed water. Repeat the assay and multiply the results by the dilution factor.\nConversions: 1uM zinc equals 6.5 ug/dL or 0.065 ppm (65 ppt).\n\nMaterials Required, But Not Provided:\nPipeting devices and accessories. Clear bottom 96-well plates (e.g. Corning Costar) and plate reader, or cuvettes and spectrophotometer for measuring OD 425nm.\n\nExamples:\nSamples were assayed in duplicate using the 96-well protocol. The zinc concentration (microg/dL) was 45.2 пїЅ 4.4 for a human serum, 49.3 пїЅ 3.2 for rat serum, 35.8 пїЅ 1.4 for rat plasma, 113 пїЅ 2 for Invitrogen fetal bovine serum, 30.8 пїЅ 1.5 for human urine, 0.99 пїЅ 0.31 for a sea water sample, <0.8 for a soil extract and a human saliva sample.

Prices direct from United States Biological

Quick response times

Exclusive Biosave savings/discounts

SPECIFICATIONS

Catalog Number

Z0449-91

Size

1Kit

References

1. Knoell, DL et al (2009). Zinc deficiency increases organ damage and mortality in a murine model of polymicrobial sepsis. Crit Care Med 37(4): 1380-8.\n2. Padiglia, A et al (2010). Sensitivity to 6-n-propylthiouracil is associated with gustin (carbonic anhydrase VI) gene polymorphism, salivary zinc, and body mass index in humans. Am J Clin Nutr 92(3): 539-45.\n3. Kelly, E et al (2011). Redistribution of labile plasma zinc during mild surgical stress in the rat. Transl Res 157(3): 139-49.

Read more on Supplier website

Applications

ELISA, IP, WB

Hosts

Rabbit

Reactivities

Hum, Mouse, Rat

More info

Applications

ELISA, IP, WB

Hosts

Rabbit

Reactivities

Hum, Mouse, Rat

More info

Applications

FC, IF, IHC, IP, WB

Hosts

Rabbit

Reactivities

Hum, Mouse, Rat, Dro/Arth, NHP

More info

Applications

ELISA, IF, IHC, WB

Hosts

Rabbit

Reactivities

Hum, Mouse, Rat, Bov, ZF/Fish

More info
Advertisehere
MtoZ Horizontal banner
MtoZ Biolabs

Latest promotion FROM:

MtoZ Biolabs
View promotion

Latest promotions

Spend less time on DNA cleanup so you can do more science. The MSB Spin PCRapace is the fastest way to purify your DNA from PCR, restriction digestion, and...

New brilliant antibodies, and new lower prices!For flow cytometry reagents in general, \"bright is better.\" The violet-excitable BD Horizon&trade; BV421 and...

As an incentive to qualify our BSA, we are offering a 20% discount when you purchase your first 100g, 500g or 1000g of any grade of Bovine Serum Albumin....

It is not every day that you are given something for nothing. We are giving away additional spectrophotometer software.Cecil Instruments have enhanced the...

We're so sure that you'll prefer Cayman Assay kits over your present brand that we're willing to give you a free assay kit to prove it!

For the past decade scientists have extensively used ATS secondary toxin conjugates to make their own targeted toxins for in vitro use.The ability to combine...

10% Discount on 2 Rabbit Polyclonal Antibody Service. With over 20 years experience, SDIX has developed into the premier US custom antibody producer,...

Did your supplier increase the price of Fetal Bovine Serum? Did they substitute the US Origin with USDA? Well say no more! Innovative Research is still...

Bulk Cytokines with Custom Vialing.20 - 50% off cytokines, growth factors, chemokines and more...For a limited time Cell Sciences is offering substantial...

Jenway&rsquo;s 73 series spectrophotometer range provides four models with a narrow spectral bandwidth of 5nm and an absorbance range of &ndash;0.3 to 2.5A,...

Are you planning to have a customised antibody made for your research?Since 2000, Everest has been producing a catalog containing thousands of affinity...